Short Keypress Duration for MFK |
(Radio Ergonomics Wide, Advanced) |
![]()
Selects the amount of time that defines how long the radio-user must press and hold the CPS-programmable Multi-Function Knob (MFK) before the radio recognizes a valid short press. This feature applies on a radio-wide basis. Time is in milliseconds (ms).
![]()
|
A
Short Keypress Duration button-press
toggles between the Multi-Function
Knob's Primary and Secondary functions, |
![]()
When the radio is model / option capable, and
when the Radio Selection field is not set to "Secondary Radio".
![]()
This Short Keypress Duration must always be a shorter period of time than the Long Keypress Duration for MFK field setting (applicable only to portable radios). |
Minimum |
Maximum |
Increments |
50 (ms) |
6200 (ms) |
50 (ms) |
ms = milliseconds |